PV2900 LHP Series (AC:110V 1-6KW)

Low Frequency Solar Inverter AC 120V | MPPT 80A | WIFI | BMS | Dual output

PV2900 LHP series is very economical pure sine wave solar inverter, AC voltage 110V/120V, AC charger inbuilt, from 20A to 60A; MPPT solar charger 80A inbuilt; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is not enough, it enables inverter to operate with all kinds of home appliances, widely selling to Latin America.

Description

Description

■ Pure sine wave output

■ 3 Steps charging

■ Overload and short-circuit protection

■ Set charging voltage/charging current.

■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V

■ Power-save mode

■ Set utility priority/ Battery priority

■ Set utility input wide/narrow range

■ Inverter voltage can be set to 120V:110V/115V/120V

■ Inverter frequency can be set to 50/60Hz

■ Set utility charging on/off switch

■ 80A MPPT charger

■ Acid or Lithium Select

■ WiFi port (optional)

■ With BMS lithium battery communication function (CAN port)

■ Dual output for smart load management

MODEL PV29-1KW-LHP PV29-1.5KW-LHP PV29-2KW-LHP PV29-3KW-LHP PV29-4KW-LHP PV29-5KW-LHP PV29-6KW-LHP
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 1P 1P 1.5P 2P 3P
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 110V / 115V / 120VAC(±10% RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
Overload 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)
AC INPUT
Voltage 110/120VAC
Selectable Voltage Range 75~135VAC (For personal computers)
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
Output Voltage Depends on battery type
Overcharge Protection S.D. 15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
PAYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
AC Input Breaker 1-3K/40A 4-6K/63A
SOLAR CHARGER
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
Maximum PV Charge Current 80A±4A
DC Voltage 12V/ 24V auto work 24V/ 48V auto work
MPPT Range @ Operating Voltage 15~95VDC @ 12V/ 30~230VDC @ 24V 30~230VDC @ 24V/ 60~230VDC @ 48V
Maximum PV Array Open Circuit Voltage 245VDC
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Dimensions (W*H*D) 274*484*174mm 274*568.5*174mm
Package Dimensions (W*H*D) 583.5*376*255mm 668.5*376*255mm
OTHER
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 1 year
CERTIFICATION & STANDARDS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)