Description
■ Built-in 30A MPPT Solar Charge Controller
■ 10A or 15A standard charging current from utility AC
■ 2 Output ports for DC load
■ AC/solar priority for charging via MFD
■ Different charging mode for different kinds of batteries
■ Overload & short-circuit protection, Battery reverse polarity protection, Deep discharge protection
■ Auto restart while AC/solar is recovering Adjustable solar and utilitycharging current
■ Support fast max charging current setting
■ Support two kinds of batteries: LiFePO4 Lithium Battery Packand Lead-acid Battery
■ Automatic activate lithium battery pack which is be over discharged no output when AC input is OK
MODEL | PV15-1512 LV | PV15-1524 LV | ||
Nominal Battery System Voltage | 12VDC | 24VDC | ||
NVERTER OUTPUT | ||||
Rated Power | 1500VA/ 1000W | |||
Waveform | Pure Sine Wave | |||
Nominal Output Voltage RMS | 120V | |||
Output Voltage Regulation | +10/-18% | |||
Output Frequency | 50Hz / 60Hz ± 1Hz | |||
Inverter Efficiency (Peak) | >90% | |||
Line Mode Efficiency | >95% | |||
Typical Transfer Time | Typical < 10ms , 15ms max | |||
AC INPUT | ||||
Voltage | 120VAC | |||
Voltage Range | 88 ~ 144VAC ± 3% | |||
Frequency Range | 45 ~ 65Hz ± 2Hz | |||
BATTERY | ||||
Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack – 12V(4 Series) 24V(8 Series) | ||||
Nominal Input Voltage | 12VDC | 24VDC | ||
Low Battery Cutoff | 10.5VDC(PB) | 11.5VDC(LI) | 21.0VDC(PB) | 23.0VDC(LI) |
Low Battery Alarm | 11.0VDC(PB) | 12.0VDC(LI) | 22.0VDC(PB) | 24.0VDC(LI) |
Low Battery Voltage Recover | 12.5VDC(PB) | 12.8VDC(LI) | 25.0VDC(PB) | 25.6VDC(LI) |
High Battery Voltage Recover | 14.5VDC(PB) | 14.3VDC(LI) | 29.0VDC(PB) | 28.6VDC(LI) |
High Battery Voltage Cutoff | 15.0VDC(PB) | 14.8VDC(LI) | 30.0VDC(PB) | 29.6VDC(LI) |
SOLAR CHARGER & AC CHARGER | ||||
Charger Voltage boost | 14.4VDC(PB) | 14.4VDC(LI) | 28.8VDC(PB) | 28.8VDC(LI) |
Charger Voltage float | 13.8VDC(PB) | 14.4VDC(LI) | 27.6VDC(PB) | 28.8VDC(LI) |
Maximum PV Charge Current | 40A (max) | |||
Maximum PV Array Power | 600W | 1200W | ||
MPPT Operating Voltage Range | 14 ~ 75VDC | 28 ~ 75VDC | ||
Maximum PV Array Open Voltage | 100VDC | |||
Maximum Efficiency | > 95% | |||
Standby Power Consumption | < 2W | |||
AC Charging Current | 20A (Can be set) | |||
Maximum Charge Current AC+PV | 60A (Can be set) | |||
BYPASS & PROTECTION | ||||
Overload Protection (SMPS Load) | FUSE | |||
Output Short Circuit Protection | FUSE | |||
Bypass Fuse Rating | 15A | |||
Max Bypass Current | 15A | |||
Battery Fuse Current | 50A x 3 | 50A x 2 | ||
OTHER | ||||
Operation Temperature Range | 0℃ to 40℃ | |||
Audible Noise | 50dB MAX | |||
Display | LED+LCD | |||
DIMENSIONS | ||||
Machine Dimension (W*H*D) | 320*267*96mm | |||
N.W | 4.5kg |