Description
■ 3 Steps charging
■ MFD (multi-function display)
■ Overload and short-circuit protection
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Power-save mode
■ Set utility priority/ Battery priority
■ Set utility input wide/narrow range
■ Inverter voltage can be set to 110V/115V/120V
■ Inverter frequency can be set to 50/60Hz
■ Set utility charging on/off switch
■ Acid or Lithium Select
■ WIFI monitoring function (optional)
■ With BMS lithium battery communication function (CAN port)
MODEL | EP30-4024 LV2 | EP30-4048 LV2 | EP30-5048 LV2 | EP30-6048 LV2 |
Nominal Battery System Voltage | 24VDC | 48VDC | 48VDC | 48VDC |
INVERTER OUTPUT | ||||
Reted Power | 4KW | 5KW | 6KW | |
Surge Rating | 12000VA | 15000VA | 18000VA | |
Capable Of Starting Electric Motor | 2HP | 3HP | ||
Waveform | Pure sine wave/ same as input (bypass mode) | |||
Nominal Output Voltage RMS | 110V/115V/120VAC ±10% (RMS) | |||
Output Frequency | 50Hz / 60Hz±0.3 Hz | |||
Inverter Efficiency(Peak) | >88% | |||
Line Mode Efficiency | >95% | |||
Power Factor | 1.0 | |||
Typical Transfer Time | 10ms(max) | |||
Overload | 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07) | |||
AC INPUT | ||||
Voltage | 120VAC | |||
Selectable Voltage Range | 75~135VAC(For Personal Computers) | |||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | |||
BATTERY | ||||
Minimum Start Voltage | (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
Low Battery Alarm | (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
Low Battery Cut off | 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
High Voltage Alarm | (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
High Battery Voltage Recover | (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
Idle Consumption-Search Mode | Load ≤50±20W(120V) | |||
CHARGER | ||||
Output Voltage | Depends on battery type | |||
Charger AC Input Breaker Rating | 3K/40A | 4-6KW/63A | ||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode) | |||
Maximum Charge Current | 60A | 30A | 35A | 40A |
BYPASS & PROTECTION | ||||
Input Voltage Waveform | Sine wave (grid or generator) | |||
Nominal Input Frequency | 50Hz or 60Hz | |||
Overload Protection (SMPS Load) | Circuit breaker | |||
Output Short Circuit Protection | Circuit breaker | |||
AC Input Breaker | 40A | 50A/63A | ||
MECHANICAL SPECIFICATIONS | ||||
Mounting | Wall Mount | |||
Machine Dimension (W*H*D) | 531*305*202mm | |||
Package Dimension (W*H*D) | 686*400*319mm | |||
OTHER | ||||
Operation Temperature Range | 0°C to 40°C | |||
Storage Temperature | -15°C to 60°C | |||
Audible Noise | 60dB MAX | |||
Display | LED+LCD | |||
Standard Warranty | 1 year |