Showing 13–21 of 21 results

See

EP2000 Pro Series (DC:12V 300-1000W)

Low Frequency Power Inverter/Charger 300W~1000W | 12V | 10~30A

EP2000 PRO series inverter is a cost effective, intelligent with UPS function. The comprehensive LCD offers user-configurable and easy-accessible button adjustment such as battery charge current, battery charge voltage, frequency, buzzer etc. It’s perfect for the user who need a simple and economical inverter,with user-friendly installnation and setting.Tower and rack design available for different choices.

Model Certification & Standards
EP20-0312 PRO/0412 PRO/0612 PRO/0812 PRO/1012 PRO CE-LVD(EN IEC62109-1:2010, EN IEC62109-2:2011)
EP20-0312 PRO/0412PRO/0512PRO/0612PRO/0812PRO/1012PRO CE-EMC+LVD(EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)
EP20-0312 PRO/0412PRO/0512PRO/0612PRO/0812PRO1012PRO IEC60950-1:2005A+1:2009+A2:2013
EP20-0312 PRO/0412 PRO/0612 PRO/0812 PRO/1012 PRO EN IEC62040-1:2019

EP2000 Pro Series (DC:24V 600-1000W)

Low Frequency Power Inverter/Charger 600W~1000W | 24V | 10~15A

EP2000 PRO series inverter is a cost effective, intelligent with UPS function. The comprehensive LCD offers user-configurable and easy-accessible button adjustment such as battery charge current, battery charge voltage, frequency, buzzer etc. It’s perfect for the user who need a simple and economical inverter,with user-friendly installnation and setting.Tower and rack design available for different choices.

Model Certification & Standards
EP20-0624 PRO/0824 PRO/1024 PRO CE-LVD(EN IEC62109-1:2010, EN IEC62109-2:2011)
EP20-1024PRO/0624PRO/0824PRO CE-EMC+LVD(EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011)
EP20-1024PRO/0624PRO/0824PRO IEC60950-1:2005A+1:2009+A2:2013
EP20-0624 PRO/0824 PRO/1024 PRO EN IEC62040-1:2019

EP3000 PRO Series (8-12KW)

Low Frequency Pure Sine Wave Inverter

Low frequency pure sine wave combined inverter&A/C charger EP3000 PRO Series 8 -12kw; Quiet,high efficiency operation front panel LED+LCD indicators and adjustable switch selectors selectable settings for flooded lead acid,Gel,or absorbed glass mat(AGM) batteries. Mainly for home and office applicances such as TV, refrigerator, fans lights and computers etc.

EP3000 LV2 Series (AC:120V 1-3KW)

Low Frequency Power Inverter/Charger 1~3KW | AC 120V | WIFI | BAT-CAN

EP3000 LV2 series is very economical pure sine wave inverter, special in north & south america market, and AC charger from 35A to 70A .Solar/AC priority configurable . When solar priority , in case its charge current lower than inverter’s charger from AC , AC will supplement to charge the batteries, to optimize charging. With low frequency transformer ,it enable the inverter to operate with all kinds of home appliances.

EP3000 LV2 Series (AC:120V 4-6KW)

Low Frequency Power Inverter/Charger 4~6KW | AC 120V | WIFI | BAT-CAN

EP3000 LV2 series is very economical pure sine wave inverter, special in north & south america market, and AC charger from 35A to 70A .Solar/AC priority configurable . When solar priority , in case its charge current lower than inverter’s charger from AC , AC will supplement to charge the batteries, to optimize charging. With low frequency transformer ,it enable the inverter to operate with all kinds of home appliances.

EP3000 PLUS Series (1-3KW)

Low Frequency Power Inverter/Charger 1~3kW | 230V | WIFI | BAT-CAN

EP3000 PLUS series is a very economical pure sine wave inverter, with AC charger from 20A to 60A; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower . With pure copper transformer, it enables inverter to operate with all kinds of home appliances.

Model Certification & Standards
EP30-1012/1024/1512/1524/2012/2024/3024/3048 PLUS CE-EMC+LVD(EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

EP3000 PLUS Series (4-6KW)

Low Frequency Power Inverter/Charger 4~6kW | 230V | WIFI | BAT-CAN

EP3000 PLUS series is a very economical pure sine wave inverter, with AC charger from 20A to 60A; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower . With pure copper transformer, it enables inverter to operate with all kinds of home appliances.

Model Certification & Standards
EP30-4024/4048/5048/6048PLUS CE-EMC+LVD(EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

EP3300 TLV Series (AC:110/220V 1-3KW)

Low Frequency Pure Sine Wave Split Phase Inverter Charger 1~3KW | AC110V/220V | MPPT 80A | WiFi | BAT-CAN

This split phase inverter EP3300 TLV series, capacity from 1KW-3KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which matches AC 110VAC/120V single phase, or two phase 220V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charge controller to build a solar home system, take use of sunshine freely and save electricity bills.

Model Certification & Standards
EP33-1012/1024/1512/1524/2012/2024/3024/3048 TLV CE-EMC+LVD(EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

EP3300 TLV Series (AC:110/220V 4-6KW)

Low Frequency Pure Sine Wave Split Phase Inverter Charger 4~6KW | AC110V/220V | MPPT 80A | WiFi | BAT-CAN

This split phase inverter EP3300 TLV series, capacity from 4KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which matches AC 110VAC/120V single phase, or two phase 220V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charge controller to build a solar home system, take use of sunshine freely and save electricity bills.

Model Certification & Standards
EP33-4024/4048/5048/6048 TLV CE-EMC+LVD(EN6100-6-3: 2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)